QLogic Adapter CIM Provider and vCenter Plug-in Release Notes Cavium Corporation. All rights reserved. Table of Contents 1. Change History 2. Known Issues 3. Notices 4. Contacting Support 1. Changes History The following changes have been made to the QLogic Adapter/E3 CIM Provider and vCenter Plug-in between versions 1.2.47-UNCERTIFIED and 1.2.47-2. Adapter Provider Version 1.6.76, E3 Adapter Provider Version 1.0.45, vCenter Plug-in Version 1.2.47 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.47: --------------------------------------------------------------- Adapter Provider: * Certified CIM Provider E3 Adapter Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.76, E3 Adapter Provider Version 1.0.45, vCenter Plug-in Version 1.2.47 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.47: --------------------------------------------------------------- Adapter Provider: * Support for new adapters E3 Adapter Provider: * None vCenter Plug-in: * Support for new FC adapters * Changed MBA boot config protocol option UNDI to PXE for Ethernet adapters * Removed MBA boot config iBFT option for HP Ethernet adapters vCenter Web Client Plug-in: * Support for new FC adapters * Changed MBA boot config protocol option UNDI to PXE for Ethernet adapters * Removed MBA boot config iBFT option for HP Ethernet adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.45, vCenter Plug-in Version 1.2.46.3 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.46.3: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Certified CIM Providers vCenter Plug-in: * Added missing AutoNeg option in MBA boot config vCenter Web Client Plug-in: * Added missing AutoNeg option in MBA boot config Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.75, E3 Adapter Provider Version 1.0.45, vCenter Plug-in Version 1.2.46.2 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.46.2: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Fixed issue with setting iSCSI boot enable vCenter Web Client Plug-in: * Fixed issue with setting iSCSI Boot enable Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.75, E3 Adapter Provider Version 1.0.45, vCenter Plug-in Version 1.2.46.1 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.46.1: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Fixed issue with setting IPv6 addresses in iSCSI Boot config vCenter Web Client Plug-in: * Fixed issue with setting IPv6 addresses in iSCSI Boot config Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.75, E3 Adapter Provider Version 1.0.45, vCenter Plug-in Version 1.2.46 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.46: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Temperature data available for NX2 adapters * ROCE information available for E4 adapters vCenter Plug-in: * Added display of temperature for NX2 adapters * Added display of NDIS parameters to show ROCE info vCenter Web Client Plug-in: * Added display of temperature for NX2 adapters * Added display of NDIS parameters to show ROCE info Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.75, E3 Adapter Provider Version 1.0.44, vCenter Plug-in Version 1.2.45.3 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.45.3: --------------------------------------------------------------- Adapter Provider: * New FC native API E3 Adapter Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * Removed debugging info from iSCSI Boot Config * Fixed issue with iSCSI Boot Config panel causing error in function data panel Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.44, vCenter Plug-in Version 1.2.45.2 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.45.2: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Fixed iSCSI boot config non-offload/offload setting vCenter Web Client Plug-in: * Fixed iSCSI boot config non-offload/offload setting Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.44, vCenter Plug-in Version 1.2.45.1 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.45.1: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed issue with updating adapters with latest mbi files. vCenter Plug-in: * Removed iSCSI boot config from the function level * Modified code to use appropriate function when setting the iSCSI boot mode * Fixed issue of Chap authentication text boxes being disabled * Fixed issue of displaying diagnostics for ESXi 6.5 * Fixed setting of iSCSI Boot Enabled in iSCSI Boot Config vCenter Web Client Plug-in: * Removed iSCSI boot config from the function level * Modified code to use appropriate function when setting the iSCSI boot mode * Fixed issue of Chap authentication text boxes being disabled * Fixed issue of displaying diagnostics for ESXi 6.5 * Fixed setting of iSCSI Boot Enabled in iSCSI Boot Config Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.43, vCenter Plug-in Version 1.2.44 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.44: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Fixed issue with target lun number in the wrong position in array for E4 adapters * Fixed E4 boot mode configuration to use appropriate number for offload * Fixed issue of iSCSI boot configuration panel not showing in UI for E4 vCenter Web Client Plug-in: * Fixed issue with target lun number in the wrong position in array for E4 adapters * Fixed E4 boot mode configuration to use appropriate number for offload Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.43, vCenter Plug-in Version 1.2.43 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.43: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Updated code to fix iSCSI boot issues vCenter Plug-in: * Added code for NPAR protocol settings for new adapter vCenter Web Client Plug-in: * Added code for NPAR protocol settings for new adapter * Fixed issue of iSCSI boot configuration not showing for E4 adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.42, vCenter Plug-in Version 1.2.42 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.42: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Fixed issue of incorrect version number reported in vCenter Server vCenter Web Client Plug-in: * Fixed issue of incorrect version number reported in vCenter Server Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.42, vCenter Plug-in Version 1.2.42 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.42: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Added code to determine iSCSI driver vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.41, vCenter Plug-in Version 1.2.42 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.42: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Modified code to use CIM port number from CIM ticket * Modified function protocol setting for new adapters vCenter Web Client Plug-in: * Modified code to use CIM port number from CIM ticket * Modified function protocol setting for new adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.41, vCenter Plug-in Version 1.2.41 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.41: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Support for new adapters vCenter Plug-in: * Moved iSCSI boot config to port level for E4 adapters * Added address redirect to iSCSI boot config * Added iSCSI boot mode (offload/non-offload) * Updated device ids for new adapters * Fixed setting of "Hide Setup Prompt" in MBA boot config vCenter Web Client Plug-in: * Fixed null pointer exception for 1 port adapter * Moved iSCSI boot config to port level for E4 adapters * Added address redirect to iSCSI boot config * Added iSCSI boot mode (offload/non-offload) * Updated device ids for new adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.39, vCenter Plug-in Version 1.2.40 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.40: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Fixed issue of firmware update with vSphere 2016 vCenter Web Client Plug-in: * Fixed issue of firmware update with vSphere 2016 Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.39, vCenter Plug-in Version 1.2.40 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.40: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed issue of slow fw update vCenter Plug-in: * Fixed issue of slow fw update * Modified code to display vmhba name in storage map for iSCSI/FCoE vCenter Web Client Plug-in: * Fixed issue of slow fw update * Modified code to display vmhba name in storage map for iSCSI/FCoE Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.38, vCenter Plug-in Version 1.2.39 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.39: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Added code to correctly display FCoE name in storage map vCenter Web Client Plug-in: * Added code to correctly display FCoE name in storage map * Modified code to display login dialog for ESXi 6.5 host when authentication fails for token authentication * Fixed issue of null pointer exceptions when navigating away from iSCSI boot config for E4 adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. * When installing CIM provider on ESXi 6.5, make sure the CIMOM is running: a) execute the following command to see if the CIMOM is enabled: esxcli system wbem get b) Make sure the "Enabled:" is "true" c) if the "Enabled" property was false, then execute the following command to enable: esxcli system wbem set -e true Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.38, vCenter Plug-in Version 1.2.38.1 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.38.1: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Display WWNN instead of DeviceName for Virtual port * Display 16Gb as Max Data Rate for 32Gb Adapters that are capped at 16Gb * Added new IDs for adapters that are capped at 16Gb * Added new IDs for 16 and 32Gb Mezz adapters * Fixed issue of storage map not showing for E4 adapter when only iSCSI is enabled * Fixed iSCSI boot config to disable/enable TCPIP settings * Added new NX2 adapter to list of adapters vCenter Web Client Plug-in: * Display WWNN instead of DeviceName for Virtual port * Display 16Gb as Max Data Rate for 32Gb Adapters that are capped at 16Gb * Added new IDs for adapters that are capped at 16Gb * Added new IDs for 16 and 32Gb Mezz adapters * Fixed issue of iSCSI/FCoE boot config for E4 adapters causing erroneous error message when they are not supposed to be available * Fixed iSCSI boot config to disable/enable TCPIP settings * Added new NX2 adapter to list of adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * Latest version of ESXi 6.5 (4233018) has resolved the login issue, but if the version being used is not the latest, please try the following workaround: * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is provided. A login dialog has been added that will appear when logging into ESXi 6.5 hosts. To enable the login dialog, please follow the instructions in "specialInst.txt" to see how to modify the configuration file to enable the login dialog. Please see included "specialInst.txt" file for how to modify the configuration file. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. If the adapters still do not appear, there is an issue with the security on the latest ESXi 6.5 beta builds. Please follow the instructions in "specialInst.txt" file for how to enable all security protocols. * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.38, vCenter Plug-in Version 1.2.38 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.38: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Fixed setting of SRIOV Vfs for E4 adapters in default mode * Updated iSCSI/FCoE boot config parameters for E4 adapters vCenter Web Client Plug-in: * Fixed setting of SRIOV Vfs for E4 adapters in default mode * Updated iSCSI/FCoE boot config parameters for E4 adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * Latest version of ESXi 6.5 (4233018) has resolved the login issue, but if the version being used is not the latest, please try the following workaround: * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is provided. A login dialog has been added that will appear when logging into ESXi 6.5 hosts. To enable the login dialog, please follow the instructions in "specialInst.txt" to see how to modify the configuration file to enable the login dialog. Please see included "specialInst.txt" file for how to modify the configuration file. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. If the adapters still do not appear, there is an issue with the security on the latest ESXi 6.5 beta builds. Please follow the instructions in "specialInst.txt" file for how to enable all security protocols. * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.38, vCenter Plug-in Version 1.2.37.1 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.37: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Support for iSCSI/FCoE Boot config for E4 adapters * Fix for mac address display * Added FCoE name for storage map * Fix for firmware update vCenter Plug-in: * Added hbaName to FCoE * Modified code for MBA boot parameters to do E4 specific boot protocol setting. * Updated list of E4 channel adapter ids to include new adapters * Removed restriction on FW update to only Channel adapters. Now all adapters have the ability to do FW update. * Added code to display colons in MAC address * Added code to hide unsupported diag tests for E3 adapters. * Removed check for CNA adapters when displaying panels * Moved iSCSI/FCoE Boot Config for E4 adapters down to function level vCenter Web Client Plug-in: * Added hbaName to FCoE * Modified code for MBA boot parameters to do E4 specific boot protocol setting. * Updated list of E4 channel adapter ids to include new adapters * Removed restriction on FW update to only Channel adapters. Now all adapters have the ability to do FW update. * Added code to display colons in MAC address * Added code to hide unsupported diag tests for E3 adapters. * Removed check for CNA adapters when displaying panels * Moved iSCSI/FCoE Boot Config for E4 adapters down to function level * Updated config file to disable ESXi 6.5 login workaround. If workaround is still necessary, the config file will need to be modified. Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * Latest version of ESXi 6.5 (4233018) has resolved the login issue, but if the version being used is not the latest, please try the following workaround: * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is provided. A login dialog has been added that will appear when logging into ESXi 6.5 hosts. To enable the login dialog, please follow the instructions in "specialInst.txt" to see how to modify the configuration file to enable the login dialog. Please see included "specialInst.txt" file for how to modify the configuration file. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. If the adapters still do not appear, there is an issue with the security on the latest ESXi 6.5 beta builds. Please follow the instructions in "specialInst.txt" file for how to enable all security protocols. * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.37, vCenter Plug-in Version 1.2.36 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.36: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Added new adapters to list of 32G adapters vCenter Web Client Plug-in: * Added new adapters to list of 32G adapters * Fixed refresh issue when only NX2 adapters are found on ESXi host * Modified code to make sure plug-in installs when vCenter Server is not installed in default location. Need to install plug-in on same drive and vCenter Server. Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * ESXi 6.5 has an issue with logging in using the token from the vCenter Server so a login dialog will appear when logging into ESXi 6.5 hosts. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. If the adapters still do not appear, there is an issue with the security on the latest ESXi 6.5 beta builds. Please follow the instructions in "specialInst.txt" file for how to enable all security protocols. * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. * When installing web client plug-in on the same Windows machine as the vCenter Server and the web client plug-in does not seem to be installed. Please make sure the plug-in is installed on the same drive as the vCenter Server. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.37, vCenter Plug-in Version 1.2.35 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.35: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed segmentation fault * Fixed issue of missing adapter information in firmware update vCenter Plug-in: * Fixed issue of SRIOV checkbox not reflecting correct state of SRIOV when all Vfs are 0 vCenter Web Client Plug-in: * Fixed issue of SRIOV checkbox not reflecting correct state of SRIOV when all Vfs are 0 * Fixed Linux installer Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * ESXi 6.5 has an issue with logging in using the token from the vCenter Server so a login dialog will appear when logging into ESXi 6.5 hosts. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. * In latest version of vCenter Server, the "Manage" tab is replaced by "Configure" tab. In this case the vSphere plug-in is in the "More" section of the left pane of the "Configure" window. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.36, vCenter Plug-in Version 1.2.34 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.34: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed issue with firmware update * Fixed issue with VLAN mode and VLAN Id not saving properly vCenter Plug-in: * Fixed missing iSCSI option in MBA boot protocol list box * Fixed display of IPv6 in iSCSI panels vCenter Web Client Plug-in: * Fixed missing iSCSI option in MBA boot protocol list box * Fixed display of IPv6 in iSCSI panels Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * ESXi 6.5 has an issue with logging in using the token from the vCenter Server so a login dialog will appear when logging into ESXi 6.5 hosts. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.35, vCenter Plug-in Version 1.2.33 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.33: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Fixed issue with DCBX protocol display vCenter Web Client Plug-in: * Fixed issue with DCBX protocol display Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * ESXi 6.5 has an issue with logging in using the token from the vCenter Server so a login dialog will appear when logging into ESXi 6.5 hosts. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.35, vCenter Plug-in Version 1.2.32 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.32: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed issues with iSCSI boot config. vCenter Plug-in: * Added iSCSI boot config and FCoE boot config for E4 adapters * Fixed issues with iSCSI boot config and FCoE boot config for E3 adapters * Fixed issue of getting appropriate driver version when only iSCSI E4 driver is enabled * Fixed display of E4 driver version when NIC driver is disabled * Fixed issue of device Id showing as decimal number instead of hex * Fixed issue of iSCSI tree node not showing link down vCenter Web Client Plug-in: * Added iSCSI boot config and FCoE boot config for E4 adapters * Fixed issues with iSCSI boot config and FCoE boot config for E3 adapters * Fixed issue of SRIOV Vfs not enabling / disabling correctly when EP mode is enabled / disabled * Fixed wrong label for iSCSI driver version in server map * Fixed issue of device Id showing as decimal number instead of hex * Fixed issue of iSCSI tree node not showing link down Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * ESXi 6.5 has an issue with logging in using the token from the vCenter Server so a login dialog will appear when logging into ESXi 6.5 hosts. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.34, vCenter Plug-in Version 1.2.31 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.31: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fix for E3/E4 adapter information getting combined into a single adapter when both are present vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * UI for iSCSI/FCoE boot config is available, but still needs work in the lower layers of the software. Do not test this. * ESXi 6.5 has an issue with logging in using the token from the vCenter Server so a login dialog will appear when logging into ESXi 6.5 hosts. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.33, vCenter Plug-in Version 1.2.31 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.31: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixes for iSCSI/FCoE related issues. vCenter Plug-in: * Updated FC adapter list * Added code to check for NIC function when allowing user to flash firmware or set boot config * Updated version numbers of drivers that implement E4 diagnostics vCenter Web Client Plug-in: * Fixed issue of BB Credit not showing in the UI * Updated FC adapter list * Added code to check for NIC function when allowing user to flash firmware or set boot config * Updated version numbers of drivers that implement E4 diagnostics Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * UI for iSCSI/FCoE boot config is available, but still needs work in the lower layers of the software. Do not test this. * ESXi 6.5 has an issue with logging in using the token from the vCenter Server so a login dialog will appear when logging into ESXi 6.5 hosts. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.32, vCenter Plug-in Version 1.2.30 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.30: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Latest versions of QLMAPIesx, qlevis, qlevfc libraries. vCenter Plug-in: * Added code to enable / disable SRIOV Vf settings based on EP mode vCenter Web Client Plug-in: * Fixed issue of changing from default mode to MF mode failing due to SRIOV checking code not performing the apropriate check * Fixed issue of NPAR data being sent when the user has made no changes * Added code to enable / disable SRIOV Vf settings based on EP mode Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * UI for iSCSI/FCoE boot config is available, but still needs work in the lower layers of the software. Do not test this. * ESXi 6.5 has an issue with logging in using the token from the vCenter Server so a login dialog will appear when logging into ESXi 6.5 hosts. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.31, vCenter Plug-in Version 1.2.29 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.29: --------------------------------------------------------------- Adapter Provider: * Certified CIM Provider E3 Adapter Provider: * Fixed issue of showing 2 adapters instead of 1 for an adapter that changed into multi-function mode * Fixed issue of each port showing as an adapter instead of a port on 40G adapter in NPAR vCenter Plug-in: * Enabled SRIOV enable/disable checkbox for E4 adapter in default mode vCenter Web Client Plug-in: * Enabled SRIOV enable/disable checkbox for E4 adapter in default mode * Fixed issue of NPAR configuration saving when no data has been changed in the UI * Fixed issue with ESXi 6.5 login failing to recover after failed login when the reason is other than unauthenticated Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * UI for iSCSI/FCoE boot config is available, but still needs work in the lower layers of the software. Do not test this. * ESXi 6.5 has an issue with logging in using the token from the vCenter Server so a login dialog will appear when logging into ESXi 6.5 hosts. If wrong credentials are entered and the login dialog does not appear again, restart the web client. For Windows, restart service "VMware Service Lifecycle Manager". For vCSA, restart the vCSA VM. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.30, vCenter Plug-in Version 1.2.28 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.28: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Added support for statistics refresh. vCenter Plug-in: * Added refresh button to NDIS statistics panel * Enabled BB Credit feature in FC parameters vCenter Web Client Plug-in: * Added refresh button to NDIS statistics panel * Enabled BB Credit feature in FC parameters * Added login dialog for ESXi 6.5 hosts Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * UI for iSCSI/FCoE boot config is available, but still needs work in the lower layers of the software. Do not test this. * ESXi 6.5 has an issue with logging in using the token from the vCenter Server so a login dialog will appear when logging into ESXi 6.5 hosts. Adapter Provider Version 1.6.72, E3 Adapter Provider Version 1.0.27, vCenter Plug-in Version 1.2.27-4 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.27-4: --------------------------------------------------------------- Adapter Provider: * Fix for flash update on new adapters E3 Adapter Provider: * Added support for E3 adapter driver qfle3. vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * UI for iSCSI/FCoE boot config is available, but still needs work in the lower layers of the software. Do not test this. Adapter Provider Version 1.6.71, E3 Adapter Provider Version 1.0.27, vCenter Plug-in Version 1.2.27-4 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.27-4: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Added code to hide IPv6 config in iSCSI boot parameters for E4 adapters * Removed protocol states in the L2NIC panel for E4 * Fixed link speed setting for MBA boot config for E4 adapters * Updated QLUtils with new adapters * Fixed display of iSCSI and FCoE boot config panels for E4 adapters vCenter Web Client Plug-in: * Added code to hide IPv6 config in iSCSI boot parameters for E4 adapters * Removed protocol states in the L2NIC panel for E4 * Fixed link speed setting for MBA boot config for E4 adapters * Updated QLUtils with new adapters * Fixed display of iSCSI and FCoE boot config panels for E4 adapters * Fixed crash when 40G E4 adapter is in the ESXi host * Added checks for null in network map Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. * UI for iSCSI/FCoE boot config is available, but still needs work in the lower layers of the software. Do not test this. Adapter Provider Version 1.6.71, E3 Adapter Provider Version 1.0.27, vCenter Plug-in Version 1.2.27-3 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.27-3: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Added support for new adapter vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. Adapter Provider Version 1.6.71, E3 Adapter Provider Version 1.0.26, vCenter Plug-in Version 1.2.27-3 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.27-3: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed enumeration of FCoE nodes in the adapter tree for E4 adapters * Fixed enumeration of targets and LUNs in the tree for E4 adapters vCenter Plug-in: * Fixed FC target port state to show Up/Down instead of a number vCenter Web Client Plug-in: * Fixed FC target port state to show Up/Down instead of a number * Fixed storage and network map for E4 adapter Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters if L2NIC is not present * E4 iSCSI MAC address is all 0's * E4 iSCSI shows IPv6 instead of IPv4 in the iSCSI information panel * E4 iSCSI Portal IP shows all 0's * E4 FCoE Port Link Keep Alive Interval shows random number * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. Adapter Provider Version 1.6.71, E3 Adapter Provider Version 1.0.25, vCenter Plug-in Version 1.2.27-2 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.27-2: --------------------------------------------------------------- Adapter Provider: * Added support for FCoE statistics reset E3 Adapter Provider: * None vCenter Plug-in: * Added workaround for using plug-in with ESXi host from vSphere 2016 vCenter Web Client Plug-in: * Added workaround for using plug-in with ESXi host from vSphere 2016 Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Storage targets and LUNs will not appear connected to E4 adapters is L2NIC is not present * Due to issue with vSphere 2016, need to manually set the user name and password into the plug-in. It will not discover adapters unless the login information for the ESXi host is added to the configuration file of the plug-in. Please see included "specialInst.txt" file for how to modify the configuration file. Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.25, vCenter Plug-in Version 1.2.27-1 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.27-1: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Added support for additional adapters * Added iSCSI/FCoE boot configuration discovery and set for E4 adapters vCenter Plug-in: * Added functionality to detect previous installation of plug-in * Modified code to remove description of adapter if there is a conflict with the descriptions of the ports on the adapter * Added support for E4 iSCSI/FCoE Boot config * Added reset button for classic Q FCoE statistics vCenter Web Client Plug-in: * Added functionality to detect previous installation of plug-in * Modified code to remove description of adapter if there is a conflict with the descriptions of the ports on the adapter * Added support for E4 iSCSI/FCoE Boot config * Added reset button for classic Q FCoE statistics Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters * Diagnostic LED test and Physical Loopback test are not supported for E4 adapters (the tests will return fail) until appropriate driver is released * E4 iSCSI/FCoE boot configuration setting are not supported * Reset for classic Q FCoE statistics is not supported until new CIM provider can be released Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.24, vCenter Plug-in Version 1.2.26 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.26: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Modified code to support ESXi 6.1 (with new binary for 6.1) vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.23, vCenter Plug-in Version 1.2.26 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.26: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Certified CIM Providers vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.23, vCenter Plug-in Version 1.2.26 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.26: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * NPAR L2NIC setting enabled for last 4 functions on each port of E4 adapters vCenter Web Client Plug-in: * NPAR L2NIC setting enabled for last 4 functions on each port of E4 adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.23, vCenter Plug-in Version 1.2.25 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.25: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * NPAR L2NIC setting disabled for first 4 functions on each port of E4 adapters vCenter Web Client Plug-in: * NPAR L2NIC setting disabled for first 4 functions on each port of E4 adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.23, vCenter Plug-in Version 1.2.24 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.24: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Fixed issue of E4 NPAR maximum bandwidth not saving correctly for functions 8, 10, 12, and 14 * Fixed reboot message for E3/E4 NPAR changes vCenter Web Client Plug-in: * Fixed reboot message for E3/E4 NPAR changes Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.23, vCenter Plug-in Version 1.2.23 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.23: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Added support for EP Mode vCenter Plug-in: * Added support for EP mode in NPAR configuration vCenter Web Client Plug-in: * Added support for EP mode in NPAR configuration Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.21, vCenter Plug-in Version 1.2.22 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.22: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Disabled NPAR L2 setting for E4 adapters vCenter Web Client Plug-in: * Disabled NPAR L2 setting for E4 adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.21, vCenter Plug-in Version 1.2.21 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.21: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * Fixed issue of not being able to disable SRIOV for E4 adapters * Fixed error when switching from multi-function mode to default mode for E4 adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown * SRIOV setting in Default mode is not available for E4 adapters Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.21, vCenter Plug-in Version 1.2.21 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.20: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Enabled SRIOV for a certain adapter vCenter Web Client Plug-in: * Enabled SRIOV for a certain adapter Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.21, vCenter Plug-in Version 1.2.20 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.19: --------------------------------------------------------------- Adapter Provider: * Certified CIM Providers E3 Adapter Provider: * Certified CIM Providers vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.21, vCenter Plug-in Version 1.2.20 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.19: --------------------------------------------------------------- Adapter Provider: * Renamed packages without version number for certification E3 Adapter Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.21, vCenter Plug-in Version 1.2.20 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.19: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None vCenter Plug-in: * Fixed issue of firmware update button shown for wrong adapter * Fixed issue of firmware update not showing for 100G adapter vCenter Web Client Plug-in: * Fixed issue of firmware update button shown for wrong adapter Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown Adapter Provider Version 1.6.70, E3 Adapter Provider Version 1.0.21, vCenter Plug-in Version 1.2.19 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.18: --------------------------------------------------------------- Adapter Provider: * Option ROM update - Always update PEP and MPI firmware to Primary region (This change only applies to QLE269x and QLE27xx adapters) E3 Adapter Provider: * None vCenter Plug-in: * Added message to reboot after NPAR changes for E4 adapter * Removed iSCSI Mac Address and FCoE WWN when there is no iSCSI or FCoE enabled vCenter Web Client Plug-in: * Added message to reboot after NPAR changes for E4 adapter * Fixed issue of wrong information shown for multi-function section in function panel * Fixed iSCSI portal and FCoE port labels in adapter tree * Removed iSCSI Mac Address and FCoE WWN when there is no iSCSI or FCoE enabled Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown Adapter Provider Version 1.6.68, E3 Adapter Provider Version 1.0.21, vCenter Plug-in Version 1.2.18 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.17: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed incorrect ASIC version for E3 adapters * Fixed title/description of some E4 adapters * Fix for firmware update for E4 adapters vCenter Plug-in: * Removed DCBX information for E3/E4 adapters * Added reboot required message for boot parameter config * Added reboot required message for NPAR config changes for E4 adapters vCenter Web Client Plug-in: * Fixed issue of storage map showing without storage adapters * Fixed display of function node label in adapter tree * Fixed code to not display multifunction info when only 1 function per port * Fixed bandwidth setting in multifunction mode dialog to prevent the total from becoming more than 100 for a port * Added reboot required message for boot parameter config * Added reboot required message for NPAR config changes for E4 adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * DCBX information for E3/E4 adapters not shown Adapter Provider Version 1.6.68, E3 Adapter Provider Version 1.0.20, vCenter Plug-in Version 1.2.17 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.16: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed firmware update for E3/E4 adapters vCenter Plug-in: * Modified SRIOV in default mode to not allow modification for E4 adapters. * Fixed script error for 1 port 100G adapter * Modified code to set max SRIOV setting to 16 for E4 adapters in Multi-function mode * Fixed code to display diagnostics panel when appropriate driver version is detected vCenter Web Client Plug-in: * Modified SRIOV in default mode to not allow modification for E4 adapters * Modified code to set max SRIOV setting to 16 for E4 adapters in Multi-function mode * Fixed code to display diagnostics panel when appropriate driver version is detected Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.68, E3 Adapter Provider Version 1.0.19, vCenter Plug-in Version 1.2.16 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.15: --------------------------------------------------------------- Adapter Provider: * Fixed issues with Dell adapter and Lenovo adapter not being recognized E3 Adapter Provider: * Fixed some missing/incorrect information during discovery vCenter Plug-in: * Added ids for Lenovo adapters * Fixed UI issues in VI plug-in NPAR configuration dialog for E4 adapters vCenter Web Client Plug-in: * Added ids for Lenovo adapters * Fixed UI issues in VI plug-in NPAR configuration dialog for E4 adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.67, E3 Adapter Provider Version 1.0.18, vCenter Plug-in Version 1.2.15 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.14: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed firmware update for E4 adapters * Fixed some incorrect data during discovery * Fixed setting NPAR configuration for E4 adapters vCenter Plug-in: * Added support for 16 function NPAR for E4 adapters * Disabled SRIOV for Dell E4 adapters * Fixed exception when reset button is clicked on adapter panel * Enabled 32G setting for 32G capable adapter * Fixed issue of blank storage map with certain adapters vCenter Web Client Plug-in: * Added support for 16 function NPAR for E4 adapters * Disabled SRIOV for Dell E4 adapters * Enabled 32G setting for 32G capable adapter * Fixed issue of blank storage map with certain adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.67, E3 Adapter Provider Version 1.0.16, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.14 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.13: --------------------------------------------------------------- Adapter Provider: * Added new adapter to list of adapters * Enabled online flash update E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed validation MBI firmware file for firmware update * Modfied code to list NPIV node and port names in VM tooltip in Storage and Network maps * Updated list of adapters supported vCenter Web Client Plug-in: * Fixed validation MBI firmware file for firmware update * Modfied code to list NPIV node and port names in VM tooltip in Storage and Network maps * Updated list of adapters supported Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * E4 firmware update is currently not working Adapter Provider Version 1.6.66, E3 Adapter Provider Version 1.0.16, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.13 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.12: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed display and configuration issues with E3 4 port adapter * Fixed display for MBI firmware version * Added missing E3 HP adapters to list of adapters vCenter Web Client Plug-in: * Fixed display and configuration issues with E3 4 port adapter * Fixed display for MBI firmware version * Added missing E3 HP adapters to list of adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * E4 firmware update is currently not working Adapter Provider Version 1.6.66, E3 Adapter Provider Version 1.0.16, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.12 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.11: --------------------------------------------------------------- Adapter Provider: * Certified CIM Providers E3 Adapter Provider: * Certified CIM Providers FCA Provider: * None vCenter Plug-in: * Fixed issue of FEC label in adapter tree for ports which do not support the feature * Removed BB Credit feature vCenter Web Client Plug-in: * Fixed issue of FEC label in adapter tree for ports which do not support the feature * Removed BB Credit feature Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * E4 firmware update is currently not working Adapter Provider Version 1.6.66, E3 Adapter Provider Version 1.0.16, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.11 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.10: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed null pointer exception error message from displaying when trying to update flash with wrong file * Modified code to display VMware device names in storage map * Added code to check for E4 Channel adapters vCenter Web Client Plug-in: * Fixed null pointer exception error message from displaying when trying to update flash with wrong file * Modified code to display VMware device names in storage map * Added code to check for E4 Channel adapters Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * E4 firmware update is currently not working Adapter Provider Version 1.6.66, E3 Adapter Provider Version 1.0.16, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.10 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.9: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fix for MBI version when MBI firmware file is updated FCA Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.66, E3 Adapter Provider Version 1.0.15, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.10 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.9: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed issue with 32G adapter vCenter Web Client Plug-in: * Fixed issue with 32G adapter Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.66, E3 Adapter Provider Version 1.0.15, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.9 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.8: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Added support to update E3 adapters with MBI file FCA Provider: * None vCenter Plug-in: * Added support to update E3 adapters with MBI file vCenter Web Client Plug-in: * Added support to update E3 adapters with MBI file Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.66, E3 Adapter Provider Version 1.0.11, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.8 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.7: --------------------------------------------------------------- Adapter Provider: * Added support for BB Credit functionality E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Added support for Tomcat 8 in installer * Added support for installing on vCenter Server 6.0 * Added support for BB Credit functionality vCenter Web Client Plug-in: * Added support for Tomcat 8 in installer * Fixed issue of installer not being able to register plug-in in certain circumstances * Added support for installing on vCenter Server 6.0 * Added support for BB Credit functionality Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.64, E3 Adapter Provider Version 1.0.11, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.7 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.6: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed issue of storage checkboxes showing for E3 Ethernet only adapters * Added HTML id attributes in special debug mode for testing automation * Added screens for MBA, iSCSI, FCoE boot configuration for E3 adapters vCenter Web Client Plug-in: * Fixed issue of storage checkboxes showing for E3 Ethernet only adapters * Added screens for MBA, iSCSI, FCoE boot configuration for E3 adapters * Restructured NPAR edit dialog to match vCenter Plug-in more closely * Fixed issue of bandwidth slider not changing properly in NPAR edit dialog Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.64, E3 Adapter Provider Version 1.0.11, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.6 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.5: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Certified CIM Providers FCA Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. * Plugins may show disabled storage settings instead of hiding them for 3400 series adapters. Adapter Provider Version 1.6.64, E3 Adapter Provider Version 1.0.11, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.6 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.5: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed issue of NX2 port data panel not showing iSCSI/FCoE driver version when iSCSI/FCoE is enumerated in tree vCenter Web Client Plug-in: * Fixed issue of NX2 port data panel not showing iSCSI/FCoE driver version when iSCSI/FCoE is enumerated in tree Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.64, E3 Adapter Provider Version 1.0.11, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.5 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.4: --------------------------------------------------------------- Adapter Provider: * Certified CIM Providers E3 Adapter Provider: * Fixed issue with missing VPD data and firmware version data FCA Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.64, E3 Adapter Provider Version 1.0.10, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.5 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.4: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed intermittent issue of adapters not enumerating FCA Provider: * None vCenter Plug-in: * Fixed issue of FCoE checkbox label not changing with checkbox state in NIC Partition Configuration dialog vCenter Web Client Plug-in: * None Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.64, E3 Adapter Provider Version 1.0.9, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.4 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.4: --------------------------------------------------------------- Adapter Provider: * FEC 16G training enable/disable E3 Adapter Provider: * Fixed update for MBA firmware FCA Provider: * None vCenter Plug-in: * Fixed duplicate port in map there there is more than one storage for NX2 adapter port * Fixed display of Session Unique Id in iSCSI target table when more than one iSCSI session is listed * Added serial number to the NX2 adapter information * Modified iSCSI target panel to only display session relevant to the target * Removed boot config and diagnostic tabs from the port panel vCenter Web Client Plug-in: * Fixed duplicate port in map there there is more than one storage for NX2 adapter port * Added code to set checkbox for SRIOV to unchecked if all SRIOV are 0 * Added FCoE statistics tab to FCoE device panel * Added serial number to the NX2 adapter information * Modified iSCSI target panel to only display session relevant to the target Known Issues: * In single function mode on an NX2 adapter, the protocol checkboxes may not match what is enumerated in the adapter tree. Adapter Provider Version 1.6.63, E3 Adapter Provider Version 1.0.8, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.3 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.3: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed issue of all multifunction SRIOV being disabled when storage protocols are enabled in the functions * Took out refresh and reset buttons from FCoE statistics for E3 adapters since the functionality is not implemented yet * Added code to set checkbox for SRIOV to unchecked if all SRIOV are 0 vCenter Web Client Plug-in: * Fixed issue of all multifunction SRIOV being disabled when storage protocols are enabled in the functions Adapter Provider Version 1.6.63, E3 Adapter Provider Version 1.0.8, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.2 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.2: --------------------------------------------------------------- Adapter Provider: * Fixed FEC setting in NVRAM E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Added reboot required message for FEC * Removed vmnic information from adapter title in maps * Removed IPv4 and IPv6 fields from Function information Its available on Windows, but not ESX * Fixed null object error when switching from Multi-function mode to single function mode * Fixed some mac addresses displayed in reverse byte order * Fixed some typos and removed duplicate information vCenter Web Client Plug-in: * Added reboot required message for FEC * Removed vmnic information from adapter title in maps * Removed IPv4 and IPv6 fields from Function information Its available on Windows, but not ESX * Fixed some mac addresses displayed in reverse byte order * Modified FCoE and iSCSI panels to match vCenter Plugin panels Adapter Provider Version 1.6.62, E3 Adapter Provider Version 1.0.8, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.1 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.1: --------------------------------------------------------------- Adapter Provider: * FEC support E3 Adapter Provider: * Fixed enumeration of iSCSI when set in the plugins FCA Provider: * None vCenter Plug-in: * Added FEC support * Modified code to show only the driver parameters for the adapters found in the server vCenter Web Client Plug-in: * Added FEC support * Added network and storage topology maps * Modified code to show only the driver parameters for the adapters found in the server Adapter Provider Version 1.6.61, E3 Adapter Provider Version 1.0.7, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.0.7 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.0.7: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Certified CIM providers FCA Provider: * None vCenter Plug-in: * Fixed issues found in network and storage topology maps * Fixed information on NX2 Port data panel vCenter Web Client Plug-in: * Fixed information on NX2 Port data panel Adapter Provider Version 1.6.61, E3 Adapter Provider Version 1.0.7, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.0.6 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.0.6: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed setting multi-function mode SRIOV values to 0 (disabled) * Added E3 adapters to network and storage topology maps vCenter Web Client Plug-in: * Modified code to dynamically change bandwidth slider as total bandwidth is modified * Fixed setting multi-function mode SRIOV values to 0 (disabled) Adapter Provider Version 1.6.61, E3 Adapter Provider Version 1.0.6, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.0.4 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.0.4: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed Protocol setting issue in single function mode FCA Provider: * None vCenter Plug-in: * Added code to set the protocols for each port in single function mode vCenter Web Client Plug-in: * Added code to set the protocols for each port in single function mode * Added code to set the SRIOV in multi function mode for each function * Modified edit dialog for E3 adapter to fit in the screen better Adapter Provider Version 1.6.61, E3 Adapter Provider Version 1.0.4, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.0.3 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.0.3: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixed Manufacturer string to be QLogic FCA Provider: * None vCenter Plug-in: * Added code to set the SRIOV in multi function mode for each function * Fixed flow control value in function information panel vCenter Web Client Plug-in: * Fixed reboot message display after successful firmware update Adapter Provider Version 1.6.61, E3 Adapter Provider Version 1.0.4, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.0.2 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.0.2: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed function display in bandwidth table vCenter Web Client Plug-in: * Fixed blank dialog after successful firmware update Adapter Provider Version 1.6.61, E3 Adapter Provider Version 1.0.4, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.0.1 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.0.1: --------------------------------------------------------------- Adapter Provider: * None E3 Adapter Provider: * Fixes for E3 adapter data FCA Provider: * None vCenter Plug-in: * Fixes for E3 adapters vCenter Web Client Plug-in: * Fixes for E3 adapters Adapter Provider Version 1.6.61, E3 Adapter Provider Version 1.0.3, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.2.0 and QLogic Adapter vSphere Web Client Plug-in Version 0.9.0: --------------------------------------------------------------- Adapter Provider: * Added fix for QLE2692 adapter E3 Adapter Provider: * Intial release FCA Provider: * None vCenter Plug-in: * Added support for E3 Adapters vCenter Web Client Plug-in: * Added support for E3 Adapters Adapter Provider Version 1.6.60, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.57 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.42: --------------------------------------------------------------- Adapter Provider: * Added support for QLE2692 adapter FCA Provider: * None vCenter Plug-in: * Fixed flash update issue for QLE2692 adapter vCenter Web Client Plug-in: * Fixed flash update issue for QLE2692 adapter Adapter Provider Version 1.6.59, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.56 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.41: --------------------------------------------------------------- Adapter Provider: * Certified CIM Providers FCA Provider: * None vCenter Plug-in: * Fixed null pointer issue in UI when getting QoS information * Updated list of adapters * Added information for 16G Mezzanine adapter which properly hides features that are not available for Mezzanine adapter vCenter Web Client Plug-in: * Updated list of adapters * Added information for 16G Mezzanine adapter which properly hides features that are not available for Mezzanine adapter Adapter Provider Version 1.6.59, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.55 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.40: --------------------------------------------------------------- Adapter Provider: * Fixed code to fail get QoS call when QoS region is not found in adapter FCA Provider: * None vCenter Plug-in: * Fixed boot configuration setting failing. * Fixed null pointer exception causing adapter panel to be blank for P3P adapter * Modified code to hide the QoS panel when the getting the QoS data fails vCenter Web Client Plug-in: * Modified code to hide the QoS panel when the getting the QoS data fails Adapter Provider Version 1.6.58, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.54 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.39: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed issue of firmware update failing with QLE2694 adapter. * Fixed issue of serdes table update button appearing for adapters that it should not. * Added message to reboot after successful preload table and serdes table update. vCenter Web Client Plug-in: * Fixed issue of serdes table update button appearing for adapters that it should not. * Added message to reboot after successful preload table and serdes table update. Adapter Provider Version 1.6.58, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.53 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.38: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * Fixed issue of Baker adapter vendor ID wild card in preload table file not being recognized during update. Adapter Provider Version 1.6.58, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.53 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.37: --------------------------------------------------------------- Adapter Provider: * Updated list of supported adapters which fixes preload and serdes update issue * Fixed issue of wrong Max speed for 16Gb adapters FCA Provider: * None vCenter Plug-in: * Fixed file upload issue which fixes preload and serdes update issue for certain adapters vCenter Web Client Plug-in: * Fixed file upload issue which fixes preload and serdes update issue for certain adapters Adapter Provider Version 1.6.57, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.52 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.36: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Updated list of supported adapters which fixes missing tabs for QLE2694 vCenter Web Client Plug-in: * Updated list of supported adapters Adapter Provider Version 1.6.57, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.51 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.35: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed issue of QLE2694 adapters not appearing in plugin vCenter Web Client Plug-in: * Fixed issue of QLE2694 adapters not appearing in plugin Adapter Provider Version 1.6.57, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.50 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.34: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * Fixed external loopback issue with Baker adapter connected to targets Adapter Provider Version 1.6.57, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.50 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.33: --------------------------------------------------------------- Adapter Provider: * Modify firmware preload table validation routine to allow wild card (SSDID/SSVID) with debug preload table file * Fixed Serdes Table update funcionality FCA Provider: * None vCenter Plug-in: * Added indication for FEC * Added targets listed in NVRAM in boot configuration when there are no targets currently connected vCenter Web Client Plug-in: * Fixed wrong string showing for internal loopback option * Fixed issue of cache not clearing for discovery * Added indication for FEC * Added success message when FC parameters are saved Adapter Provider Version 1.6.55, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.49 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.32: --------------------------------------------------------------- Adapter Provider: * Fixed Serdes Table update functionality * Added support for FEC FCA Provider: * None vCenter Plug-in: * Added Serdes Table Update functionality * Removed Brocade feature restriction on Baker adapters (adapter fw version must be 8.1.0 or above) * Fixed issue of data rate FC parameters not setting correctly vCenter Web Client Plug-in: * Added Serdes Table Update functionality * Removed Brocade feature restriction on Baker adapters (adapter fw version must be 8.1.0 or above) * Fixed issue of data rate FC parameters not setting correctly * Fixed issue with NPIV not showing in Storage map. * Fixed issue of result message not showing after FC parameters are saved. Adapter Provider Version 1.6.54, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.48 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.31: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Added check for Baker adapter in loopback test * Added code to hide test beacon function on virtual ports * Updated GWT version to 2.5.1 vCenter Web Client Plug-in: * Added check for Baker adapter in loopback test * Added code to hide test beacon function on virtual ports * Fixed crash when NPIV nodes are present * Removed extra NPIV nodes listed in adapter tree Adapter Provider Version 1.6.54, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.47 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.30: --------------------------------------------------------------- Adapter Provider: * Certified CIM Providers FCA Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.54, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.47 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.30: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed issue of negative value for DCE Transmitted Unipackets count vCenter Web Client Plug-in: * Fixed issue of negative value for DCE Transmitted Unipackets count Adapter Provider Version 1.6.54, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.46 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.29: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * Fixed missing Npiv nodes in adapter tree * Enabled FC loopback test for all adapters * Fixed FC parameter connection option value setting when connection option is supposed to not changeable Adapter Provider Version 1.6.54, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.46 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.28: --------------------------------------------------------------- Adapter Provider: * Removed iSCSI parameters Delayed ACK and Serialize Task Mgmt Cmds FCA Provider: * None vCenter Plug-in: * Removed iSCSI parameters Delayed ACK and Serialize Task Mgmt Cmds * Fixed VPD information to not show "Non Standard Tag" * Fixed incorrect link status for NPAR * Fixed Loopback test missing for Baker * Fixed Temperature tab missing for Baker vCenter Web Client Plug-in: * Removed iSCSI parameters Delayed ACK and Serialize Task Mgmt Cmds * Fixed VPD information to not show "Non Standard Tag" * Fixed incorrect link status for NPAR * Fixed Loopback test missing for Baker * Fixed Temperature tab missing for Baker Adapter Provider Version 1.6.53, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.45 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.27: --------------------------------------------------------------- Adapter Provider: * Updated code to support Baker adapter FCA Provider: * None vCenter Plug-in: * Updated code to support Baker adapter * Added code to disable beaconing for Mezz adapters * Added code to disable Brocade features for Mezz adapters vCenter Web Client Plug-in: * Updated code to support Baker adapter * Added code to disable beaconing for Mezz adapters * Added code to disable Brocade features for Mezz adapters Adapter Provider Version 1.6.52, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.44 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.26: --------------------------------------------------------------- Adapter Provider: * Certified CIM Providers FCA Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.52, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.44 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.26: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Removed code to hide loop only option in FC parameters for 16G and 32G adapters vCenter Web Client Plug-in: * Removed code to hide loop only option in FC parameters for 16G and 32G adapters * Added error message for invalid FC configuration connection option "loop only" with 16G data rate Adapter Provider Version 1.6.52, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.43 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.25: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed issue of FC port nodes changing order in the tree when FA WWPN is enabled * Added code to update type of loop back test depending on type of adapter * Took out unnecessary reboot message from QoS save * Added code to hide loop only option in FC parameters for 16G and 32G adapters * Added code to show QoS tab in NPAR data panel vCenter Web Client Plug-in: * Fixed issue of FC port nodes changing order in the tree when FA WWPN is enabled * Added code to update type of loop back test depending on type of adapter * Took out unnecessary reboot message from QoS save * Added code to hide loop only option in FC parameters for 16G and 32G adapters * Added code to show QoS tab in NPAR data panel * Modified installer to only install on SSL enabled Tomcat server Adapter Provider Version 1.6.52, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.42 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.24: --------------------------------------------------------------- Adapter Provider: * Fix for iSCSI loopback FCA Provider: * None vCenter Plug-in: * Bug fixes for QoS vCenter Web Client Plug-in: * Bug fixes for QoS Adapter Provider Version 1.6.51, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.41 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.23: --------------------------------------------------------------- Adapter Provider: * Added QoS support for FC port (requires FC Drivers ESX 5.1 version 934.5.40 or ESX 5.5 version 1.1.33) FCA Provider: * None vCenter Plug-in: * Added QoS support for FC port (requires FC Drivers ESX 5.1 version 934.5.40 or ESX 5.5 version 1.1.33) * Removed code to hide the CT Ping and CT Trace Route for ESXi 5.5 vCenter Web Client Plug-in: * Added QoS support for FC port (requires FC Drivers ESX 5.1 version 934.5.40 or ESX 5.5 version 1.1.33) * Removed code to hide the CT Ping and CT Trace Route for ESXi 5.5 Adapter Provider Version 1.6.50, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.40 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.22: --------------------------------------------------------------- Adapter Provider: * Support for D-Port, Fabric Assigned WWN, Fabric Assigned Boot LUN FCA Provider: * None vCenter Plug-in: * Added code for D-Port, Fabric Assigned WWN, Fabric Assigned Boot LUN vCenter Web Client Plug-in: * Added code for D-Port, Fabric Assigned WWN, Fabric Assigned Boot LUN Adapter Provider Version 1.6.49, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.39 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.21: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Removed Data LUN data from the Server SSD Storage Utilization graph in the Server data panel * Removed SSD Used for LUN from the Adapter SSD Storage Utilization graph in the FCA adapter panel vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.49, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.38 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.21: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed typo in Configure Maximum Outstanding IOs for Targets dialog title * Removed Data LUN data from the Server SSD Storage Utilization graph vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.49, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.37 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.21: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Added back missing "Set Target Alias" command in FC Cached Adapter Network panel vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.49, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.36 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.21: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Removed FCA commands: "Configure Data LUN on Adapter's SSD" "Add Flash Array LUN to Adapter drive list" "Remove Flash Array LUN from Adapter drive list" vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.49, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.35 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.21: --------------------------------------------------------------- Adapter Provider: * Fix for firmware update FCA Provider: * None vCenter Plug-in: * Updated adapter list for firmware update * Hide LUN list when empty in LUN assign dialog * Added SRIOV icons in Network Map vCenter Web Client Plug-in: * Updated adapter list for firmware update * Added SRIOV icons to Network Map * Added iSCSI loopback test Adapter Provider Version 1.6.48, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.34 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.20: --------------------------------------------------------------- Adapter Provider: * Certified CIM Providers FCA Provider: * Certified CIM Providers vCenter Plug-in: * Removed CT Ping and CT Trace Route feature for ESXi 5.5 vCenter Web Client Plug-in: * Removed CT Ping and CT Trace Route feature for ESXi 5.5 Adapter Provider Version 1.6.48, FCA Provider Version 1.0.30, vCenter Plug-in Version 1.1.33 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.19: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * HBAmgmtApi V2.103.6.4 vCenter Plug-in: * None vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.48, FCA Provider Version 1.0.28, vCenter Plug-in Version 1.1.33 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.19: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed FCA firmware update failure on ESX 5.5 U1 * Added functionality to remove LUN from queue in the dialog "Assign Adapter cache to LUNs" * Fixed missing iSCSI flashing button for 83xx adapter * Fixed FC statistics display (now table covers width of panel) * Fixed FC Ping status report for each target (now the status is in the correct row) vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.48, FCA Provider Version 1.0.28, vCenter Plug-in Version 1.1.32 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.19: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * Certified CIM Providers vCenter Plug-in: * None vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.48, FCA Provider Version 1.0.28, vCenter Plug-in Version 1.1.32 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.19: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * HBAmgmtApi V2.103.6.2 vCenter Plug-in: * None vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.48, FCA Provider Version 1.0.26, vCenter Plug-in Version 1.1.32 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.19: --------------------------------------------------------------- Adapter Provider: * CT Ping and CT Trace Route support added FCA Provider: * None vCenter Plug-in: * CT Ping and CT Trace Route support added vCenter Web Client Plug-in: * CT Ping and CT Trace Route support added Adapter Provider Version 1.6.47, FCA Provider Version 1.0.26, vCenter Plug-in Version 1.1.31 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.18: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Updated text in FCA SAN data panel. vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.47, FCA Provider Version 1.0.26, vCenter Plug-in Version 1.1.30 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.18: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Modified code to hide adapter firmware update button for iSCSI adapter. vCenter Web Client Plug-in: * BUg fixes Adapter Provider Version 1.6.47, FCA Provider Version 1.0.26, vCenter Plug-in Version 1.1.29 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.17: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fixed issue with NPAR NIC eSwitch refresh. vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.47, FCA Provider Version 1.0.26, vCenter Plug-in Version 1.1.28 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.17: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Bug fixes vCenter Web Client Plug-in: * Bug fixes Adapter Provider Version 1.6.47, FCA Provider Version 1.0.26, vCenter Plug-in Version 1.1.27 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.16: --------------------------------------------------------------- Adapter Provider: * Fix for recognizing QME2662 adapter during flash update FCA Provider: * Included HBAmgmtApi V2.100.0 vCenter Plug-in: * Fixed issue of failed firmware update message when writing flash file takes too long vCenter Web Client Plug-in: * FC ping diagnostic function was added * Added panel for FCA target node * Added panel for FCA LUN node * Added FCA transceiver table * Fixed issue of failed firmware update message when writing flash file takes too long * Bug fixes Adapter Provider Version 1.6.46, FCA Provider Version 1.0.23, vCenter Plug-in Version 1.1.26 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.15: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.46, FCA Provider Version 1.0.23, vCenter Plug-in Version 1.1.24 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.15: --------------------------------------------------------------- Adapter Provider: * Fix for flash update on 8100 series adapters. FCA Provider: * None vCenter Plug-in: * None vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.45, FCA Provider Version 1.0.23, vCenter Plug-in Version 1.1.24 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.15: --------------------------------------------------------------- Adapter Provider: * Bug Fixes FCA Provider: * Bug Fixes vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.45, FCA Provider Version 1.0.22, vCenter Plug-in Version 1.1.23 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.15: --------------------------------------------------------------- Adapter Provider: * Bug Fixes FCA Provider: * Bug Fixes vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * Fixed issue with saving NIC function parameters * Changed code for validating version number of FW preload table file. * IEEE parameters added to Ethernet DCBX parameters * FCA SAN discovery and panels added Adapter Provider Version 1.6.44, FCA Provider Version 1.0.21, vCenter Plug-in Version 1.1.22 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.14: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.44, FCA Provider Version 1.0.21, vCenter Plug-in Version 1.1.21 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.14: --------------------------------------------------------------- Adapter Provider: * Bug Fixes FCA Provider: * Bug Fixes vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * Added code to show NPAR type tab when NPAR is disabled for an NPAR function * Moved “General” information in some panels into tabs to allow for more space for other tabs in the panel * Added QConvergeConsole sub tab to VMware Cluster Manage tab to allow the user to manage all of the adapters found in a cluster of hosts Adapter Provider Version 1.6.43, FCA Provider Version 1.0.20, vCenter Plug-in Version 1.1.20 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.13: --------------------------------------------------------------- Adapter Provider: * Bug Fixes FCA Provider: * Bug Fixes vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * Added code to display NIC tabs for Helga adapter * Fixed hiding of NPAR tab when SR-IOV is enabled * Fixed iSCSI exception thrown when using iSCSI driver version 644 * Added WoL and PXE settings to Ethernet parameters * Added firmware versions for NIC, FC, and iSCSI to adapter information screen * Added code to display MPI field only when applicable * Added code to get bandwidth data for Helga adapter * Added code to check if iSCSI IP address is already in use before allowing user to set it in the parameters * Added eSwitch port statistics refresh * Added code to restrict diagnostics tab to display only on port function 0 when the adapter is P3 Adapter Provider Version 1.6.42, FCA Provider Version 1.0.19, vCenter Plug-in Version 1.1.11 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.12: --------------------------------------------------------------- Adapter Provider: * Added support for PX/WOL/iSCSI Loopback tests. FCA Provider: * Added support for Data Lun vCenter Plug-in: * Support mirror adapter for write-back * Support data lun creation and deletion vCenter Web Client Plug-in: * Fixed intermittent bandwidth data retrieval issue * Added SR-IOV panel * Added DCBX TLV panel for Helga NIC function Adapter Provider Version 1.6.41, FCA Provider Version 1.0.18, vCenter Plug-in Version 1.1.10 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.11: --------------------------------------------------------------- Adapter Provider: * SR-IOV support. FCA Provider: * Beacon support moved to port level from adapter level. * Added DCBX panel for Ethernet vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * Added DCBX panel for Ethernet Adapter Provider Version 1.6.40, FCA Provider Version 1.0.17, vCenter Plug-in Version 1.1.09 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.10: --------------------------------------------------------------- Adapter Provider: * Bug Fixes FCA Provider: * Optimization in LUN retrieval for speed and memory usage vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * Disabled Flash Update feature for Helga iSCSI * Added DCBX TLV panels for Ethernet * Added bandwidth charts to physical port data panels * Fixed text for LR Enable checkbox in FC parameters edit dialog * Modified behavior when there are no adapters found for the host by not showing the host icon in the tree and displaying a message that “No adapter data found” * Fixed flash test for NIC diagnostics Adapter Provider Version 1.6.39, FCA Provider Version 1.0.16, vCenter Plug-in Version 1.1.08 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.8: --------------------------------------------------------------- Adapter Provider: * Bug Fixes FCA Provider: * None vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * Added Network Map to server panel * Added Storage Map to server panel * Added FC Transceiver tab to FC and NPAR tabs. * Added Enable LR to FC parameters * Modified NPAR panel to use radio buttons instead of tabs for selecting the NPAR function panels. * Fixed issue with iSCSI boot selection causing class exception being thrown * Fixed issue with protocol string accumulating too many protocol strings when switching between ports. * Updated code for flash update from the VI Plug-In code * Fixed issue of wrong icons being shown for FC and iSCSI adapters. * Modified code to make refresh and host connect/disconnect more stable. * Added FCoE tab and its sub panels from the VI Plug-In to the FC data panel and the NPAR data panel * Added SRIOV support to adapter data panel. * Added FC Temperature tab to the FC data panel and the NPAR data panel * Updated some colors (in Bandwidth Assignment panel and the section headers) to match the VMware Web Client design specification * Fixed issue Bandwidth panel not showing the FCoE and Ethernet bandwidth allocations in the pie chart Adapter Provider Version 1.6.38, FCA Provider Version 1.0.16, vCenter Plug-in Version 1.1.06 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.6: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.38, FCA Provider Version 1.0.16, vCenter Plug-in Version 1.1.05 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.6: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.38, FCA Provider Version 1.0.16, vCenter Plug-in Version 1.1.04 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.6: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.38, FCA Provider Version 1.0.16, vCenter Plug-in Version 1.1.03 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.6: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.38, FCA Provider Version 1.0.16, vCenter Plug-in Version 1.1.02 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.6: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.38, FCA Provider Version 1.0.16, vCenter Plug-in Version 1.1.01 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.6: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * Bug fixes. * Latest API and HCLI Integrated vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.38, FCA Provider Version 1.0.15, vCenter Plug-in Version 1.1.00 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.6: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * Bug fixes. vCenter Plug-in: * Bug Fixes vCenter Web Client Plug-in: * None Adapter Provider Version 1.6.38, FCA Provider Version 1.0.14, vCenter Plug-in Version 1.0.99 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.6: --------------------------------------------------------------- Adapter Provider: * Bug fixes. FCA Provider: * HCLI installed in the /usr/lib/cim directory. * Adapter Health * Adapter LED * Latest API Integrated. * Bug fixes. vCenter Plug-in: * Adapter Health for 10000 series adapters. * Adapter LED for 10000 series adapters. * Bug Fixes vCenter Web Client Plug-in: * Resolved more issues revolving around the host connect/disconnect. Especially a freeze due to connecting a host that starts as disconnected. Adapter Provider Version 1.6.37, FCA Provider Version 1.0.13, vCenter Plug-in Version 1.0.98 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.4: --------------------------------------------------------------- Adapter Provider: * Bug fixes. FCA Provider: * Addition of HCLI to the provider. * Bug fixes. vCenter Plug-in: * Modify LUN caching and bug fixes for 10000 series. * SR-IOV added at the adapter level. * FCoE configuration for 8200 and 8300 series * FCoE Information. vCenter Web Client Plug-in: * Fixed problem of class cast exception when trying to set the iSCSI boot parameters. * Fixed problem of supported protocol string repeating the protocols in the physical port display. * Updated firmware update code to match vCenter plug-in firmware update code. * Fixed FC port icon for FC adapter. * Re-factored code to handle driver versions after refresh better. Adapter Provider Version 1.6.36, FCA Provider Version 1.0.12, vCenter Plug-in Version 1.0.97 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.3: --------------------------------------------------------------- Adapter Provider: * None. FCA Provider: * None. vCenter Plug-in: * Detailed message for flash update operation with delay. vCenter Web Client Plugin-in: * Fixed problem of server data not being displayed after the web client refresh is done. Adapter Provider Version 1.6.36, FCA Provider Version 1.0.12, vCenter Plug-in Version 1.0.96 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.2: --------------------------------------------------------------- Adapter Provider: * Updated iSDMAPI. FCA Provider: * None. vCenter Plug-in: * Fix to display FC Statistics with Targets. vCenter Web Client Plugin-in: * Updated code for displaying tables to resize when data changes. * Fixed problem with switching between hosts when running plugin in vSphere Web Client 5.5. * Fixed problem of wrong data displayed in Bandwidth panel when clicking between NPAR function nodes in the tree. * Setup application to display the proper panels for the release configuration. Namely: - Support discovery and inventory data for all adapters (except 10000 series adapters) - Flash update - NPAR configuration for CNA - Boot selection configuration Adapter Provider Version 1.6.35, FCA Provider Version 1.0.12, vCenter Plug-in Version 1.0.95 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.06: --------------------------------------------------------------- Adapter Provider: * Added SR-IOV support. FCA Provider: * Support for save capture file for 10000 series adapters * HBAMgmtAPI v2.75.4.0 * Support for Reset Adapter to default only for 10000 series adapters. vCenter Plug-in: * Support for save capture file for 10000 series adapters * Support for Reset Adapter to default only for 10000 series adapters. * UI changes for 10000 Series adapters. vCenter Web Client Plugin-in: * Added Fibre Channel diagnostics (Loop back test, read/write buffer test, and firmware debug dump) * Fixed issue of table not resizing properly when the browser window is resized. * Added Beacon test for Fibre Channel. * Added Ethernet diagnostics (tests and firmware debug dump) * Added iSCSI diagnostics (ping and firmware debug dump) Adapter Provider Version 1.6.34, FCA Provider Version 1.0.11, vCenter Plug-in Version 1.0.94 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.04: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * Support for ESXi 5.5 * HBAMgmtAPI v2.74.4.0 vCenter Plug-in: * Minor UI changes to FC Port Connection Options and Lun Type for 10000 Series adapters. vCenter Web Client Plugin-in: * None Adapter Provider Version 1.6.34, FCA Provider Version 1.0.10, vCenter Plug-in Version 1.0.93 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.04: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fix for the installer to detect user defined Tomcat directories. vCenter Web Client Plugin-in: * Added dialogs for editing the driver parameter settings for Ethernet, iSCSI, and Fibre Channel. The edit buttons are enabled on the screens under the host node in the adapter tree. Adapter Provider Version 1.6.33, FCA Provider Version 1.0.10, vCenter Plug-in Version 1.0.92 and QLogic Adapter vSphere Web Client Plug-in Version 0.8.03.1: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * New DCBX Tabs that includes sub functions to support DCBX for all adapters. * Fix to display FC Statistics with targets connected. * Fix to prompt users to change personality before saving. vCenter Web Client Plugin-in: * Updated code for displaying firmware buttons for adapter node screens. This code is updated from the VI plug-in code and has the same limitations as the current VI plug-in. Adapter Provider Version 1.6.33, FCA Provider Version 1.0.10 and vCenter Plug-in Version 1.0.91: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * None Adapter Provider Version 1.6.32, FCA Provider Version 1.0.10 and vCenter Plug-in Version 1.0.90: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * Integrated newer version of HBAMgmtAPI vCenter Plug-in: * None Adapter Provider Version 1.6.31, FCA Provider Version 1.0.9 and vCenter Plug-in Version 1.0.89: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Updated CIM libraries. * Installer support for Windows 2012 platform. Adapter Provider Version 1.6.31, FCA Provider Version 1.0.9 and vCenter Plug-in Version 1.0.88: --------------------------------------------------------------- Adapter Provider: * Fix for 25xx flash update operation. FCA Provider: * None vCenter Plug-in: * Fix for vCenter Plug-in installer on vCenter Server 5.0 platform. Adapter Provider Version 1.6.30, FCA Provider Version 1.0.9 and vCenter Plug-in Version 1.0.88: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fix for vCenter Plug-in installer on vCenter Server 5.0 platform. Adapter Provider Version 1.6.30, FCA Provider Version 1.0.9 and vCenter Plug-in Version 1.0.87: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Cluster topology showing Adapter and LUN cache connection. Adapter Provider Version 1.6.30, FCA Provider Version 1.0.9 and vCenter Plug-in Version 1.0.86: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * Fix for Refresh to synchronize with HCLI. Adapter Provider Version 1.6.30, FCA Provider Version 1.0.9 and vCenter Plug-in Version 1.0.85: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * SSD Smart Drive Info vCenter Plug-in: * SSD Drive SMART info is now displayed in the SSD Drive panel * Adapter and LUN statistics monitoring is active. * Fix for displaying the LUN Statistics. Adapter Provider Version 1.6.30, FCA Provider Version 1.0.8 and vCenter Plug-in Version 1.0.84: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * Fix for Cluster creation with member node - (Bug ID 8001) vCenter Plug-in: * Fix for disable cache for a SAN - (Bug ID 7927) * Adapter and LUN Statistics monitoring (beta) * Fix to show all the available members in the remove member operation - (Bug ID 8004) Adapter Provider Version 1.6.30, FCA Provider Version 1.0.7 and vCenter Plug-in Version 1.0.83: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * Restart Adapter Feature Added. vCenter Plug-in: * Restart Adapter Feature Added. * Displaying Error messages instead of error codes. Adapter Provider Version 1.6.30, FCA Provider Version 1.0.6 and vCenter Plug-in Version 1.0.82: --------------------------------------------------------------- Adapter Provider: * None FCA Provider: * None vCenter Plug-in: * LUN cache statistics. * UI enhancements. * Fix to restrict the Cache Pool Size for LUN Caching. CIM Provider Version 1.6.30 and vCenter Plug-in Version 1.0.81: --------------------------------------------------------------- CIM Provider: * None vCenter Plug-in: * Setting "Point to Point Only" Connection Option for 2600 Series Adapters. CIM Provider Version 1.6.30 and vCenter Plug-in Version 1.0.80: --------------------------------------------------------------- CIM Provider: * Fix for Flash Update on 8200 Series Adapters. vCenter Plug-in: * None CIM Provider Version 1.6.22 and vCenter Plug-in Version 1.0.64: --------------------------------------------------------------- CIM Provider: * Fix for NIC diagnostics on ESXi4.1 vCenter Plug-in: * Increase in the File upload size limit for Flash update files. * Flash update disabled for iSCSI Adapters. CIM Provider Version 1.6.22 and vCenter Plug-in Version 1.0.63: --------------------------------------------------------------- CIM Provider: * Fix for NIC diagnostics on ESXi4.1 vCenter Plug-in: * Fixing NIC diagnostics panel for continuous diagnostics run. * Moved the Beacon support at the port level. CIM Provider Version 1.6.21 and vCenter Plug-in Version 1.0.62: --------------------------------------------------------------- CIM Provider: * Added flash update support for some new adapters. vCenter Plug-in: * Added flash update support for some new adapters. * Cosmetic UI changes for flash/preload update. * Moved Beacon test from protocol level to port level. CIM Provider Version 1.6.20 and vCenter Plug-in Version 1.0.61: --------------------------------------------------------------- CIM Provider: * Fixes for NIC Diagnostics test for 8300 Series Adapters. * Fix for PSOD issue due to opening character devices * Displaying NPAR tabs correctly for 8200 series. * Fix for flash update failure in 8300 series. vCenter Plug-in: * None CIM Provider Version 1.6.18 and vCenter Plug-in Version 1.0.56: --------------------------------------------------------------- CIM Provider: * Fix for flash update operation on 8300 Series Adapters. * Added Beacon diag test support. vCenter Plug-in: * Added Beacon diag test support. CIM Provider Version 1.6.19 and vCenter Plug-in Version 1.0.59: --------------------------------------------------------------- CIM Provider: * NIC Diagnostics test for 8300 Series Adapters. * Firmware Preload Table Update for FC/FCoE Adapters. vCenter Plug-in: * Fix for flash update of 8300 Series Adapters. * Fix to show the correct data rate for 2600 Series Adapters. CIM Provider Version 1.6.18 and vCenter Plug-in Version 1.0.56: --------------------------------------------------------------- CIM Provider: * Fix for flash update operation on 8300 Series Adapters. * Added Beacon diag test support. vCenter Plug-in: * Added Beacon diag test support. CIM Provider Version 1.6.17 and vCenter Plug-in Version 1.0.55: -------------------------------------------------------- CIM Provider: * Fix up the model name display for 8300 Series Adapters. * Flash update support for additional adapters models. vCenter Plug-in: * Displaying correct model name for 8300 Series Adapters (iSCSI). * Displaying ip address at tree menu for 8300 Series Adapters (iSCSI). * Fixed the file version (MBI version) for uploaded flash images. CIM Provider Version 1.6.16 and vCenter Plug-in Version 1.0.53: -------------------------------------------------------- CIM Provider: * Fix up the model name display for 8300 Series Adapters. * Invalid SFP status displayed when applicable. vCenter Plug-in: * Lunsize in GB for iSCSI. * Transceiver tab displayed for non Mezz adapters. CIM Provider Version 1.6.15 and vCenter Plug-in Version 1.0.53: -------------------------------------------------------- CIM Provider: * Flash update support for additional adapters. * Avoiding FW Reset while saving the iscsi configuration * Support for saving some iSCSI parameters. vCenter Plug-in: * Lunsize in GB for iSCSI. * Transceiver tab displayed for non Mezz adapters. CIM Provider Version 1.6.15 and vCenter Plug-in Version 1.0.52: -------------------------------------------------------- CIM Provider: * Flash update support for additional adapters. * Avoiding FW Reset while saving the iscsi configuration * Support for saving some iSCSI parameters. vCenter Plug-in: * Removal of Enable MSI option for 8300 series adapters. * Firmware Debug Dump option enabled for 8300 series adapters. CIM Provider Version 1.6.15 and vCenter Plug-in Version 1.0.51: -------------------------------------------------------- CIM Provider: * Flash update support for additional adapters. * Avoiding FW Reset while saving the iSCSI configuration * Support for saving some iSCSI parameters. vCenter Plug-in: * Transceiver Tab has been disabled for Mezz Cards. * Enable LIP Reset parameter has been disabled for 2400, 2500, and 2600 / 8300 series adapters CIM Provider Version 1.6.15 and vCenter Plug-in Version 1.0.50: -------------------------------------------------------- CIM Provider: * Flash update support for additional adapters. * Avoiding FW Reset while saving the iscsi configuration * Support for saving some iSCSI parameters. vCenter Plug-in: * Fix for VM power state not getting reflected properly * Fix to work-around bad driver parameters CIM Provider Version 1.6.14 and vCenter Plug-in Version 1.0.49: -------------------------------------------------------- CIM Provider: * Fix for updating 8300 series Adapters with multiboot package FW 5.00.19. vCenter Plug-in: * Fix for Problem on vCenter Plug-in topology screen where the lined connection between the iSCSI LUN and the datastore containing VMs is not visible. * Fix for Bandwidth Radio button when NPAR is disabled. CIM Provider Version 1.6.14 and vCenter Plug-in Version 1.0.48: -------------------------------------------------------- CIM Provider: * Fix for updating 8300 series Adapters with flash image firmware 5.00.19. vCenter Plug-in: * Fix to Update Adapter Flash Image on OEM-branded 8200 Series adapters * Fix to retrieve Firmware Dump on 8200 Series adapters * Fix to Update Flash Image on 8100 Series adapters 2. Known Issues NIC Diagnostic Test fails on ESX 4.1 environment. 3. Notices Information furnished in this document is believed to be accurate and reliable. However, Cavium Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. Cavium Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. Cavium Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. Cavium Corporation assumes no responsibility for any errors that may appear in this document. 4. Contacting Support For further assistance, contact QLogic Technical Support at: http://support.qlogic.com Trademarks Accelera, Accelerating Cluster Performance, InfiniCon Systems, InfiniNIC, InfiniPath, InfiniView, QLA, QLogic, the QLogic logo, ReadyPath, SANdoctor, SANsurfer, and SilverStorm are registered trademarks of Cavium Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners. (c) Copyright 2009-2017. All rights reserved worldwide. QLogic, the QLogic logo, and the Powered by QLogic logo are registered trademarks of Cavium Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.